ERCES and BDA installation in Texas — done right, the first time.

If your Texas building falls under IFC §510, first-responder radios have to work inside every corner of it. We design, install, test, and re-certify the ERCES / BDA systems that make that happen — across 691 cities in 13 U.S. states — 291 of them in Texas alone, and expanding — backed by RSI and Honeywell/Fiplex authorization. Not sure if you're in scope? Our Building Signal Check tells you in 60 seconds.

Building Signal Check™ — free 60-second ERCES scoping for Texas building owners. Backed by 291 Texas AHJs and Zion's licensed BDA division.

Building Signal Check — the tool

Four questions about your building: size, height, jurisdiction, and current radio coverage. Sixty seconds. We return a clear answer on whether you're in IFC §510 / NFPA 1225 scope, what your AHJ has adopted, and what the next step looks like.

Backed by 291 Texas AHJs (part of Building Signal Check's 691-city, 13-state footprint — constantly expanding) — the same data we use internally for permit submittals.

Start the Check →

The Zion BDA division

BDA / ERCES is its own division with its own technicians, its own platform tools (PCTEL, iBwave, RSI / Honeywell / Fiplex authorized), and its own dedicated email line: BDA@zion.us.

The dedicated division site at zion.us/bda has the full picture:

When ERCES applies to you

Generally any of the following puts a building in IFC §510 scope:

  • New construction over 50,000 ft² (varies by AHJ; some Texas AHJs use 25,000 ft²)
  • Buildings four or more stories
  • Below-grade space over 25% of floor area
  • Substantial renovation that triggers AHJ re-review
  • Buildings already with BDA that need annual testing

The Building Signal Check walks you through it in under a minute.

What grid-square testing looks like

Joel Sadowsky conducting an NFPA 1225 grid-square signal survey inside a Texas warehouse — testing public-safety radio coverage bay by bay
NFPA 1225 acceptance and annual testing requires signal-strength measurements taken at the center of every 40×40 ft (1,600 ft²) grid square throughout the building — plus 100% coverage in critical areas (stairwells, fire pump rooms, fire command centers).

Pass criteria are stricter than most owners expect: −95 dBm or stronger in 95% of general-occupancy grid squares, 100% in critical areas, and FCC-licensed donor signal validation. We've walked these surveys across 100+ Texas buildings. The data goes into a written report your AHJ accepts.

Answers to the two questions owners always ask

One company. One report. One bill.

You shouldn't have to chase contractors to keep people safe.

We run every fire-protection system in your Texas building under one account. One technician team. One AHJ-ready report after each visit. One monthly bill. Start with a free 48-hour compliance audit — no commitment, no sales pitch, just a written answer to the question "are we compliant right now?"